When mains power fails, the cost is rarely the electricity. It is the corrupted database, the CCTV gap during the incident, the production line that has to be re-seeded, the server that will not come back cleanly. A correctly specified uninterruptible power supply (UPS) carries the load through the outage, or at minimum holds it up long enough for a controlled shutdown.
DCD Distribution has supplied power and cabling infrastructure in Malaysia since 1997. We distribute APC by Schneider Electric and Mycam UPS systems, batteries and cabinets to contractors, system integrators and resellers nationwide, from our Puchong warehouse in Selangor and our headquarters in Skudai, Johor.
The topology decides what your equipment actually experiences during a power event. Get this right before worrying about brand.
Best for: desktops, POS terminals, routers, NVRs, small office IT and home CCTV.
Runs equipment from mains and transfers to battery when supply fails. Automatic voltage regulation (AVR) corrects the sags and brownouts common on Malaysian supply without draining the battery. There is a brief transfer time, which ordinary IT equipment tolerates without issue.
APC Back-UPS · APC Smart-UPS SMT and SMX
Best for: servers, data rooms, medical and laboratory equipment, industrial control panels.
Continuously converts incoming AC to DC and back again, so the load is always fed from a clean, regenerated waveform. There is no transfer time and no exposure to input disturbances. This is what to specify when a momentary break is unacceptable.
APC Easy UPS SRV · APC Smart-UPS Ultra · Mycam three-phase
Undersize it and the UPS drops the load exactly when you need it. Oversize it and you have paid for capacity that will never be used. A quick starting point:
Add roughly 20–25% headroom over your measured load to allow for growth and battery ageing. Runtime is a separate decision from capacity: if you need more than the usual 5–15 minutes, specify a long-run model with external battery packs. Send us your load schedule and we will size it for you.
Every uninterruptible power supply range we distribute in Malaysia, plus the racks and accessories that go with them.
Add up the wattage of everything the UPS must carry, then allow around 20-25% headroom for future load and battery ageing. As a rough guide: a desktop or POS terminal needs 650-1000VA, a small server or NVR with a monitor 1500-3000VA, a full comms rack 3-10kVA, and a factory or data room with three-phase supply 10kVA and above. Send us your load list and we will size it properly.
A line-interactive UPS runs your equipment from mains and switches to battery when the supply fails, correcting minor voltage swings with AVR along the way. An on-line (double-conversion) UPS continuously rebuilds the waveform, so there is no transfer time at all. Line-interactive suits offices, CCTV and general IT. Choose on-line for servers, medical and laboratory equipment, and anything sensitive to a brief break in supply.
A standard UPS is designed to bridge short outages and give you a controlled shutdown, typically 5 to 15 minutes at half load. Where you need longer, specify a long-run or extended-runtime model paired with external battery packs - both the APC Easy UPS SRV -IL range and the Mycam Long Run models are built for this.
Yes. DCD Distribution is a wholesaler and distributor supplying contractors, system integrators and resellers across Malaysia, with dealer pricing tiers and project quotations. We stock from Puchong, Selangor and our headquarters in Skudai, Johor.
We carry APC by Schneider Electric across the Back-UPS, Easy UPS and Smart-UPS ranges, and Mycam for tower, rack-mount and three-phase cabinet UPS, batteries and battery cabinets.